00-12
(2.2) Inspections on male terminals
Perform the inspection by applying test probes directly to the
pins.
CAUTION
.
Be careful not to short-circuit pins together with the test
probes. With control unit connectors, short-circuiting of
pins can cause damage to the control unit’s internal circuit-
ry.
When using a multimeter to check continuity, do not allow the
test probes to touch the wrong terminals.
1.2 Inspection of connectors
(1) Visual inspection
Check that the connectors are fitted together securely.
Check whether wires have been separated from their terminals
due to pulling of the harness.
Check that male and female terminals fit together tightly.