EasyManua.ls Logo

Mitsubishi 6M60-TL - Thermostat; Water Pump

Mitsubishi 6M60-TL
330 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14-4
2. Thermostat
The thermostat is a bottom bypass
type that uses a wax-filled pellet as its
flow-regulating element. When the
wax is heated, it melts from solid to liq-
uid, changing its total volume. This al-
lows the valve to open or close in
accordance with the coolant tempera-
ture, regulating and adjusting the flow
of coolant to the radiator and to the
water pump (bypassing the radiator).
3. Water Pump
The water pump has a drain hole to
prevent coolant from entering the unit
bearing in case of a defect in the unit
seal.
STRUCTURE AND OPERATION

Table of Contents

Related product manuals