14-10
Removal sequence
Installation sequence
Follow the removal sequence in reverse.
CAUTION
Install each hose clamp to the angle indicated in the illustration so that sufficient clearance is assured be-
tween the hose clamp and its surrounding parts.
Tightening torque (Unit: N·m {kgf·m})
Mark Parts to be tightened Tightening torque Remarks
Clamp 3.9 ± 0.6 {0.4 ± 0.06}
Clamp 4 to 5 {0.4 to 0.5}
Eyebolt (joint pipe mounting) 25 {25}
1 Water hose
2 Eyebolt
3 Joint pipe
4 Water hose
5 Water hose
6 EGR cooler water pipe
7 Water hose
8 Water hose
9 EGR cooler water pipe
10 Water hose
EGR: Exhaust gas recirculation