14
14-29
Special tools (Unit: mm)
Removal procedure
Removal: Impeller
Removal: Flange
Inspection procedure
Inspection: Impeller-to-water pump shaft interference
• If the measurement does not comply with the standard value, re-
place the defective part(s).
CAUTION
• Even if the measurement complies with the standard value,
reassembly must not be carried out more than twice.
Inspection: Flange-to-water pump shaft interference
• If the measurement does not comply with the standard value, re-
place the defective part(s).
CAUTION
• Even if the measurement complies with the standard value,
reassembly must not be carried out more than twice.
Mark Tool name and shape Part No. Application
MH062192 Removal of impeller puller
Impeller puller
AB
49
± 1 φ 10