Inspection procedure
Inspection: Alternator
(1) Alternator output current (bench test)
Connect the alternator as illustrated.
CAUTION
Wires with sufficient thickness should be used for wiring
and each connection should be securely fastened.
B: Terminal B
E: Terminal E
L: Terminal L
R: Terminal R
Increase load resistance to the maximum (condition under which
the load current hardly flows).
Turn switch A and B ON.
Run alternator at 5000 rpm for 30 minutes by adjusting load re-
sistance so that electric current can conform to the following
standard.
Alternator nominal current
Measure the current at each specified revolution of alternator.
If the measured value deviates from the standard value, disas-
semble and check alternator.
(2) Adjustment voltage of regulator (bench test)
Connect the alternator as illustrated.
B: Terminal B
E: Terminal E
L: Terminal L
R: Terminal R
Turn switch ON.
Run alternator at low speeds.
Increase the speed of alternator to 5000 rpm and measure the
voltage (adjustment voltage) at this speed. At the same time,
make sure that the current is 5 amperes or less at 5000 rpm.
If the measured value deviates from the standard value, do as
follows:
If higher than the standard value: Replace the regulator.
If lower than the standard value: Inspect the alternator related
parts before replacing the regulator.
Current
Approx. 45 A