187
-
'20 • PAC-SM-351
Thi-A
[ ]
Operation check,drain pump motor test run
Temperature sensorRemote control
Model capacity setting
SW6
Terminal blockPower source)( mark
TB1
TB2
SW2
Remote control communication address
SW7-1
Thi-A
Thi-R1,2,3
Thc
Terminal blockSignal line)( mark
Temperature sensorReturn air
Temperature sensorHeat exchanger
Drain pump motor
Fan motor
DM
Fuse
F1,2
Connector
CNB-Z
FMi
DescriptionItem
Draft prevention function motor
AM1-4
Louver motor
Float switch
LM1-4
FS
Indication lampRed-Inspection
LED2
Indication lampGreen-Nomal operation
LED3
PIS
Motion sensor
Humidity sensor
HS
SW5
Plural units MasterSlave setting
Color marks
Meaning of marks
Mark Color
Blue
BK
BL
Brown
Orange
BR
OR
Red
RD
Black
Mark Color
Yellow
WH
YE
Gray
YellowGreen
GY
YEGN
White
CNTA
BL
12
CNI
BL
CNJ1
WH
CNJ2
GY
AM4AM1 AM2 AM3
6
5
4
3
2
1
CNN
YE
Thi-R3
Thi-R2
Thi-R1
2
1
CNC
WH
CNH
BK
12
DM
12
CNR
WH
M
CNM1
WH
FMi
M
F2
CNB
BK
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
2
1
RD
RD
RD
RD
YE
BK
BK
YE
1 4 5 6 7
FS
X
Y
X
Y
TB2
WH
BK
Thc
TB1
YEGN
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
BLRD BR OR WH
+12
+12
2.0A
YEGN
※1
BKBK
RDWH
LM4LM1 LM2 LM3
MM
1
M M
2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5
MM
1
M M
BK
2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5
BK BK BK BK BK BK BK BK BK
WH WH WH WH WH WH WH WH WH WHBL BL BL BL BLBL BL BL BL
BL
RD RD RD RD RD RD RD RD RD RD
E1
F1
CNWO
WH
135
YEGN
RD
3.15A
WH
Power circuit
Indoor unit PCB
CNL
BK
3
1
2
BK
BK
BK
Option
1
2
volt-free contact
HS
BK
BK
Remote operation input
BK BK BK BK BK BK BK BK BK BK RD RD RD RD RD RD RD RD RD RD
CNJ3
WH
CNJ4
WH
WH WH WH WH WH WH WH WH WH WHBL BL BL BL BL
BL
BL BL BL BL
1
2
Earth
3
Power source line
Signal line
1 2
3
CNW3
WH
1
3
WH
BL
The line between
indoor unit and outdoor unit
XR1
XR5
Operation
Heating
Compressor ON
Inspection
Prepare on site
XR2
XR3
XR4
1
2
3
4
5
6
+12
Remote operation input
volt-free contact
CNT
BL
CNM2
WH
BLRD BR OR WH
PIS
3
1
2
Remote control
SW2
SW6SW7
LED3LED2
Prepare on site
SW5
Notes 1. indicates wiring on site.
  
2. See the wiring diagram of outdoor unit about the line between
  
3. Use twin core cord
0.3mm at remote control line.
2
indoor unit and outdoor unit.
  
4. Do not put remote control line alongside power source line.
  
5. Draft prevention function
(※1)
is provided on the panel TC-PSAE-5AW-E only.
(b) Ceiling casette-4 way compact type (FDTC)
Models FDTC50VH, 60VH
PJF000Z516
B