PARAMETERS
91
!
You can also set the detection of the frequency used exclusively for reverse rotation.
This function is effective for switching the timing of electromagnetic brake operation
between forward rotation (rise) and reverse rotation (fall) during vertical lift operation etc.
Parameter
Number
Factory
Setting
Setting
Range
Remarks
42 6Hz 0 to 400Hz
43 9999
0 to 400Hz,
9999
9999: Same as Pr. 42 setting
<Setting>
Refer to the figure below and set the corresponding parameters:
!
When Pr. 43
9999, the Pr. 42 setting applies to forward rotation and the Pr. 43
setting applies to reverse rotation.
!
Assign the terminal used for FU signal output with any of Pr. 190 to Pr. 192 (output
terminal function selection).
Refer to page 150 for Pr. 190 to Pr. 192 (output terminal function selection).
Pr.42
Pr.43
Output frequency (Hz)
Output signal
FU
Time
OFF
ON
OFF
ON
OFF
Reverse
rotation
Forward
rotation
Note: Changing the terminal assignment using Pr. 190 to Pr. 192 may affect the
other functions. Make setting after confirming the function of each terminal.
Pr. 44, Pr. 45
'
''
'
Refer to Pr. 7.
Pr. 46
'
''
'
Refer to Pr. 0.
Pr. 47
'
''
'
Refer to Pr. 3.
Pr. 48
'
''
'
Refer to Pr. 9

Table of Contents