PARAMETERS
163
(3)Read Pr. 903 and show the current setting of the gain frequency.
(Pr. 902, Pr. 904 and Pr. 905 can also be adjusted similarly.)
MODE SET REV
STOP
RESET
FWD
PU
SET
0 to 9 0 to 9
Most significant
digit flickers.
Middle digit
flickers.
Least significant
digit flickers.
Current setting of gain frequency
SET
SET
SET
"
Parameter setting mode
Using the key, choose the "parameter setting mode" as in (2)-1).
MODE
×
9
times
×
3
times
PU
EXT
Hz
RUN
A
(4)Set a gain frequency in Pr. 903 and show the analog voltage A/D value across
terminals 2-5 in %. (when the frequency is set to 80Hz)
Press for 1.5s
PU
EXT
Hz
RUN
A
PU
EXT
MON
Hz RUN
A
Current setting of
gain frequency
"
Changing the gain
frequency
Press to change
the set frequency.
"
Analog voltage A/D value (%)
across terminals 2-5
SET
PU
EXT
MON
Hz
RUN
A
In any of the methods in (5) to (7) on the following page,
continue the setting until the analog voltage A/D value
flickers. If you end the setting here, the gain frequency
change will not be reflected.