Reference
Setting and
Adjustment
1.2
Setting parameter
#
OB
T
ietting
range
(Unit)
Description
The offset value where the analog speed refer-
ence signal is used is set.
Generally, it is
adjusted using the offset variable resistor
on the NC.
Standard setting: 0
Parameter
Speed
reference
offset
Signed deci-
mal notation
-999
-
+999)
VOP
oc
OD
VON
Not used.
0 should be set.
The gain against the speed reference signal
is set.
Assume that 1000 is 1 unit, the
real speed reference signal is made by multi-
plying the set data by the external speed
reference signal.
Generally,
it si adjusted by the gain volume
of the NC.
Standard setting: 1000
Decimal
(0
-
1150)
Speed
referenct
signal gainVGP
OE
Not used.
0 should be set.
VGN
CSN2
2nd cushion
time constant
OF
Not used.
0 should be set.
Decimal
Whether data of the parameters
ill
to
Y20
is valid or invalid is set.
0: Invalid
1: Valid as speed setting unit data
When this parameter is set to
'l",
the input
signals to the SF-OR card connector CONC be-
comes valid as data being set to the parameters
Yll
to
Y20.
For details, see the "Speed
selection signal function specification
BNP-A0801-22".
Decimal
10
DTYP Data type
11
12
13
14
15
16
17
18
19
1A
19
1c
-
1D
DTOl Data 1
DT02
Data 2
DT03 Data 3
DT04
Data 4
DT05
Data 5
DT06 Data 6
DT07
Data 7
DT08 Data 8
DT09
Data 9
DTlO
Data 10
DTll
Data 11
DT12
Data 12
When the
#lo
data parameter type is set to
"I",
these parameters
become
valid.
The speed
reference which is selected by the speed selec-
tion signal is set to each data.
The data is
set by the motor speed in such a manner that it
does not exceed the motor maximum speed which
is set by
131
TSP.
Decimal
DT13
Not used. 0 should be set.
DT14
Not used. 0 should be set.
1E
-
1F
DT15
Not used.
0 should be set.
Standard setting: 40 times
(The input signal is checked every approx.
1.3
msec.)
0
to
9999
times
Input signal
check times
20
DT16
-190-