FX3G INSTALLATION MANUAL
8
FX3G-24M_
AC Power Supply Type
FX3G-24M_
DC Power Supply Type
FX3G-40MR/ES
AC Power Supply Type
FX3G-60MR/ES
AC Power Supply Type
4. SPECIFICATIONS AND WIRING
DANGER: DESIGN PRECAUTIONS
Make sure to have the following safety circuits outside of the PLC
to ensure safe system operation even during external power supply
problems or PLC failure. Otherwise, malfunctions may cause serious
accidents.
Most importantly, have the following: an emergency stop circuit,
a protection circuit, an interlock circuit for opposite movements
(such as normal vs. reverse rotation), and an interlock circuit
(to prevent damage to the equipment at the upper and lower
positioning limits).
Note that when the PLC CPU detects an error, such as a
watchdog timer error, during self-diagnosis, all outputs are turned
off. Also, when an error that cannot be detected by the PLC CPU
occurs in an input/output control block, output control may be
disabled. External circuits and mechanisms should be designed to
ensure safe machinery operation in such a case.
Note that when an error occurs in a relay, triac or transistor
output device, the output could be held either on or off. For output
signals that may lead to serious accidents, external circuits and
mechanisms should be designed to ensure safe machinery
operation in such a case.
Do not bundle the control line together with or lay it close to the
main circuit or power line. As a guideline, lay the control line at least
100mm (3.94”) or more away from the main circuit or power line.
Noise may cause malfunctions.
Install module so that excessive force will not be applied to the built-
in programming connectors, power connectors or I/O connectors.
Failure to do so may result in wire damage/breakage or PLC failure.
Even if the AC power supply causes an instantaneous power failure
for less than 10 ms, the PLC can continue to operate.
Even if the DC power supply causes an instantaneous power failure
for less than 5 ms, the PLC can continue to operate.
If a long-time power failure or an abnormal voltage drop occurs,
the PLC stops, and output is turned off. When the power supply is
restored, it will automatically restart (when the RUN input is on).
DANGER: WIRING PRECAUTIONS
Cut off all phases of the power supply externally before installation
or wiring work in order to avoid damage to the product or electric
shock.
CAUTION: WIRING PRECAUTIONS
Connect the AC power supply to the dedicated terminals specified in
this manual. If an AC power supply is connected to a DC input/output
terminal or DC power supply terminal, the PLC will burn out.
Do not wire vacant terminals externally. Doing so may damage the
product.
Use class D grounding (grounding resistance of 100Ω or less) with
a wire of 2mm² or thicker on the grounding terminal of the FX3G
Series main unit. However, do not connect the ground terminal at the
same point as a heavy electrical system.
When drilling screw holes or wiring, make sure cutting or wire debris
does not enter the ventilation slits. Failure to do so may cause fire,
equipment failures or malfunctions.
Input/output wiring 50 to 100m (164'1" to 328'1") long will cause
almost no problems of noise, but, generally, the wiring length should
be less than 20m (65'7") to ensure the safety.
S/S
NL
X1
X2
X3
X4
X5
X6
X7
X10
X11
X12
X13
X14
X15
Y2Y0
COM1 COM2COM0 COM3
Y3
Y4
Y6
Y7
Y10
Y11
COM4
FX
3G
-24MR/ES
0V
24V
Y1 Y5
X0
S/S X1
X2
X3
X4
X5
X6
X7
X10
X11
X12
X13
X14
X15
Y2Y0
COM1 COM2COM0 COM3
Y3
Y4
Y6
Y7
Y10
Y11
COM4
Y1 Y5
X0
FX
3G
-24MT/DS
S/S
NL
X1
X2
X3
X4
X5
X6
X7
X10
X11
X12
X13
X14
X15
Y2Y0
COM1 COM2COM0 COM3
Y3
Y4
Y6
Y7
Y10
Y11
COM4
FX
3G
-24MR/ES
0V
24V
Y1 Y5
X0
S/S X1
X2
X3
X4
X5
X6
X7
X10
X11
X12
X13
X14
X15
Y2Y0
COM1 COM2COM0 COM3
Y3
Y4
Y6
Y7
Y10
Y11
COM4
Y1 Y5
X0
FX
3G
-24MT/DS
X3S/S X1
X2NL X4
X5
X6
X7
X10
X11
X12
X13
X14
X15
X16
X17
Y2Y0
COM1 COM2COM0
0V
24V
Y3
COM3
Y6
Y7
COM4
Y12
Y13
COM5
Y5 Y11
X20
X21
X22
X23
X24
X25
X26
X27
Y14
Y15
Y16
Y17
FX3G
-40
MR/ES
Y1 Y4 Y10
X0
X0
S/S
NL
X1
X2
X3
X4
X5
X6
X7
X10
X11
X12
X13
X14
X15
X16
X17
Y2Y0
COM1 COM2COM0
0V
24V
Y3
COM3
Y6
Y7
COM4
Y12
Y13
COM5
Y5 Y11
X20
X21
X22
X23
X24
X25
X26
X27
Y16
Y17
Y22
Y23
Y24
Y25
Y26
Y27
X30
X31
X32
X33
X34
X35
X36
X37
Y15
FX
3G
-60MR/ES
X40
X41
X42
X43
Y1 Y 4 Y10 Y14 Y20
COM6
Y21
COM7