E-150
FX Series PLC User's Manual - Data Communication Edition
Inverter Communication
12 Related Data
12.5 FREQROL Inverter Parameter List
Automatic
acceleration
/deceleration
−−
61 Reference current 61 Reference current
- −
62
Reference value at
acceleration
62
Reference value at
acceleration
63
Reference value at
dcceleration
63
Reference value at
deceleration
64
Starting frequency for
elevator mode
- −
− 65 Retry selection 65 Retry selection 65 Retry selection 65 Retry selection
− 66
Stall prevention
operation reduction
starting frequency
66
Stall prevention
operation reduction
starting frequency
66
Stall prevention
operation reduction
starting frequency
66
Stall prevention
operation reduction
starting frequency
Retry
67
Number of retries at
alarm occurrence
67
Number of retries at
alarm occurrence
67
Number of retries at
fault occurrence
67
Number of retries at
fault occurrence
68 Retry waiting time 68 Retry waiting time 68 Retry waiting time 68 Retry waiting time
69
Retry count display
erase
69
Retry count display
erase
69
Retry count display
erase
69
Retry count display
erase
− 70
Special regenerative
brake duty
70
Special regenerative
brake duty
70
Special regenerative
brake duty
70
Special regenerative
brake duty
− 71 Applied motor 71 Applied motor 71 Applied motor 71 Applied motor
− 72
PWM frequency
selection
72
PWM frequency
selection
72
PWM frequency
selection
72
PWM frequency
selection
− 73 Analog input selection 73 Analog input selection 73 Analog input selection 73 Analog input selection
− 74 Input filter time constant 74 Input filter time constant 74 Input filter time constant 74 Input filter time constant
− 75
Reset selection/
disconnected PU
detection/PU stop
selection
75
Reset selection/
disconnected PU
detection/PU stop
selection
75
Reset selection/
disconnected PU
detection/PU stop
selection
75
Reset selection/
disconnected PU
detection/PU stop
selection
− 76
Alarm code output
selection
76
Alarm code output
selection
- − - −
− 77
Parameter write
selection
77
Parameter write
selection
77
Parameter write
selection
77
Parameter write
selection
− 78
Reverse rotation
prevention selection
78
Reverse rotation
prevention selection
78
Reverse rotation
prevention selection
78
Reverse rotation
prevention selection
− 79
Operation mode
selection
79
Operation mode
selection
79
Operation mode
selection
79
Operation mode
selection
Simple
magnetic
flux vector
control
80
Motor capacity
(simple magnetic flux
vector control)
80 Motor capacity 80 Motor capacity 80 Motor capacity
−−
81 Number of motor poles 81 Number of motor poles - −
82 Motor excitation current 82 Motor excitation current 82 Motor excitation current
83 Motor rated voltage 83 Motor rated voltage 83 Motor rated voltage
84 Rated motor frequency 84 Rated motor frequency 84 Rated motor frequency
89
Speed control gain
(magnetic flux vector)
89
Speed control gain
(advanced magnetic
flux vector)
- −
90 Motor constant (R1) 90 Motor constant (R1) 90 Motor constant (R1) 90 Motor constant (R1)
−− −
91 Motor constant (R2) 91 Motor constant (R2)
- −
92 Motor constant (L1) 92 Motor constant (L1)
93 Motor constant (L2) 93 Motor constant (L2)
94 Motor constant (X) 94 Motor constant (X)
95
Online auto tuning
selection
- −
96
Auto tuning setting/
status
96
Auto tuning setting/
status
96
Auto tuning setting/
status
FREQROL F700 Series FREQROL A700 Series FREQROL E700 Series FREQROL D700 Series
Function
Pr
No.
Name
Pr
No.
Name
Pr
No.
Name
Pr
No.
Name