Comfort setting hot water
Comfort setting hot water
The integrated water heater is a coil model and is heated by
circulating water, which is heated by the heat pump.
During normal consumption it is enough to run the heat
pump to supply the different tapping points of the house with
hot water. The temperature of the hot water in the water heater
then varies between the set values.
Undersection1.0[N]Hotwatertemp.onpage93thereisa
complete description of menu settings for hot water
temperatures.
Available volume
<HMA100V, HMA100VM>
8/min
12/min
16/min
0
100
200
300
400
500
600
50 53 56 59 62 65
Stop temp. HW (°C )
Supply water volume (
)
Hot water volume
*
This graph is based on the following conditions :
Inlet water temperature : 15°C
Outlet water temperature : 40°C
Outdoor air temperature : 7°C
Start temp. HW setting :
55°C (Stop temp. HW setting is 58°C or higher)
Stop temp. HW -3°C (Stop temp. HW setting is
lower than 58°C )
<HMS140V>
MT300
HotwaterSupplyisunlimitedincase8
/min at the condition
as the capacity is bigger than hot water supply.
MT500
Prioritizing
When the water temperature in the tankdrops, heat pump
operation shifts to hot water production. In case there is
demand for both hot water and heating/cooling for long time,
operation mode is periodically switched between hot water and
heating/cooling. For details, see Menu 1.0 Hot water temp and
Menu8.5.0Periodsettings.
Extra Hot Water
Inall Extrahotwater”functions,thetemperatureofthehot
waterincreasestemporarily.Thetemperatureisrstincreased
to an adjustable level by the compressor (Menu 1.5) and then
the electric heater is energized until the water temperature
reaches the stop temperature (Menu 1.4).
Temporary“Extrahotwater”isactivatedmanually,whilsttime
based extra hot water is activated using the settings made in the
control computer.
When:
■ “A”appearsabovethe
icon, temporary extra hot water
is active.
■ “B”appearsabovethe
icon, time based extra hot water
is active.
NOTE
Extra hot water” usually means that the electric heater
is activated regardless of Allow add heat setting (menu
8.2.1) and therefore increases the electrical
consumption.
8/min
12/min
16/min
0
100
200
300
400
500
600
50 53 56 59 62 65
Stop temp. HW (°C )
Supply water volume (
)
Hot water volume
*
This graph is based on the following conditions :
Inlet water temperature : 15°C
Outlet water temperature : 40°C
Outdoor air temperature : 7°C
Start temp. HW setting :
55°C (Stop temp. HW setting is 58°C or higher)
Stop temp. HW -3°C (Stop temp. HW setting is
lower than 58°C )
TBD
0
50
100
150
200
250
300
350
400
450
50 53 56 59 62 65
12 /min
16 /min
Stop temp HW (°C)
Supply water volume (
)

Table of Contents

Other manuals for Mitsubishi HMA100V

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi HMA100V and is the answer not in the manual?

Mitsubishi HMA100V Specifications

General IconGeneral
BrandMitsubishi
ModelHMA100V
CategoryHeat Pump
LanguageEnglish

Related product manuals