EasyManua.ls Logo

Mitsubishi Melservo-J2-SUPER series - Page 36

Mitsubishi Melservo-J2-SUPER series
91 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2 - 17
2. LINEAR SCALES
Connection cable connection examples (1)
The following cable wiring examples assume that the linear encoder (linear scale) is connected directly to
CN2 of the servo amplifier.
(1) Connection example of up to 5m wiring length (This connection example assumes that the following
operating combination is satisfied.)
[Operating combination]
Used Wire Size Encoder (Scale) Model Encoder (Scale) Side Output Cable Specifications
AWG22 RGH26 Renishaw make output cable 0.5m
[Connection example]
(Note 1)
Renishaw make linear encoder
(linear scale)
19
12
20
11
7
17
1
P5
LG
P5
LG
M
R
MR
R
LG
6
16
Plate
M
D
MD
R
S
D
P5
LG
M
R
MR
R
P5
LG
Inner
S
D
(Note 2)
CN2
Servo motor
Encoder
(Note 3)
Servo amplifier
MR-J2S-
B
-PY096/S096
/P
/Q
Limit switch output (Note 4)
(Note 5)
10120-3000PE, 10320-52F0-008
(3M make or equivalent)
50m or less (2 wire type)
5m or less
Note 1. Do not connect the linear encoder (linear scale) that is not indicated in this specification.
2. Connect the shield wire to the plate (ground plate) in the connector securely.
3. For the wiring to the servo motor, refer to the standard connection examples in Chapter 3 and the Instruction Manual of the MR-
J2S-
B standard model.
4. A limit switch signal cannot be imported directly to the servo amplifier. When using a limit switch, use a photocoupler for
isolation as shown above. Contact the scale manufacturer for detailed specifications of the limit switch.
5. The encoder (scale) home position (reference mark) data is sent to the servo amplifier by serial communication.
6. Contact the scale manufacturer for detailed specifications such as the combinations, models, types, etc. of the linear encoder
(linear scale) side output cable and connector.
/P, /Q
5V
0V
Renishaw make
linear encoder (linear scale)
Photocoupler
isolation
[Linear encoder side connector] (Note 6)
Applicable
Housing
D Sub 15 Pin Female
Equivalent
Inner 15
P5 7, 8
LG 2, 9
MR 10
MRR 1
SD Case

Table of Contents