Loading...
5. HOW TO USE THE PROGRAM
5 - 31
(c) Feed length multiplication ([Pr. PT03])
Set the feed length multiplication factor (STM) of the position data.
[Pr. PT03] setting
Position data input range
[mm] [inch] [degree] (Note) [pulse] (Note)
_ _ _ 0
(initial value)
-999.999 to 999.999 -99.9999 to 99.9999
-360.000 to 360.000 -999999 to 999999
_ _ _ 1 -9999.99 to 9999.99 -999.999 to 999.999
_ _ _ 2 -99999.9 to 99999.9 -9999.99 to 9999.99
_ _ _ 3 -999999 to 999999 -99999.9 to 99999.9
Note. The feed length multiplication setting ([Pr. PT03]) is not applied to the unit multiplication factor. Adjust the unit
multiplication factor in the electronic gear setting ([Pr. PA06] and [Pr. PA07]).
(2) Signal
Selecting a program with DI0 to DI3 and switching on ST1 perform the positioning operation according to
the set program. At this time, ST2 (Reverse rotation start) is disabled.
Item Device to be used Setting
Program operation method
selection
MD0 (Operation mode selection 1) Switch on MD0.
Program selection
DI0 (Program No. selection 1)
DI1 (Program No. selection 2)
DI2 (Program No. selection 3)
DI3 (Program No. selection 4)
Refer to section 2.3 (1).
Start ST1 (Forward rotation start) Switch on ST1 to execute the program operation.