7. PARAMETERS
7 - 4
No. Symbol Name
Initial
value
Unit
Control
mode
CP CL
PB47 NHQ3 Notch shape selection 3 0000h
PB48 NH4 Machine resonance suppression filter 4 4500 [Hz]
PB49 NHQ4 Notch shape selection 4 0000h
PB50 NH5 Machine resonance suppression filter 5 4500 [Hz]
PB51 NHQ5 Notch shape selection 5 0000h
PB52 VRF21 Vibration suppression control 2 - Vibration frequency 100.0 [Hz]
PB53 VRF22 Vibration suppression control 2 - Resonance frequency 100.0 [Hz]
PB54 VRF23 Vibration suppression control 2 - Vibration frequency damping 0.00
PB55 VRF24 Vibration suppression control 2 - Resonance frequency
damping
0.00
PB56 VRF21B Vibration suppression control 2 - Vibration frequency after
gain switching
0.0 [Hz]
PB57 VRF22B Vibration suppression control 2 - Resonance frequency after
gain switching
0.0 [Hz]
PB58 VRF23B Vibration suppression control 2 - Vibration frequency damping
after gain switching
0.00
PB59 VRF24B Vibration suppression control 2 - Resonance frequency
damping after gain switching
0.00
PB60 PG1B Model loop gain after gain switching 0.0 [rad/s]
PB61 For manufacturer setting 0.0
PB62 0000h
PB63 0000h
PB64 0000h

Table of Contents