EasyManua.ls Logo

Mitsubishi MR-JE-100A - Page 370

Mitsubishi MR-JE-100A
396 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10. COMMUNICATION FUNCTION (MITSUBISHI ELECTRIC GENERAL-PURPOSE AC SERVO PROTOCOL)
10 - 11
(6) I/O device prohibition (command [9] [0])
Command Data No. Description Setting range
Control
mode
Frame
length
CP CL
[9] [0] [0] [0] Turns off the input devices except EM2, LSP and LSN,
external analog input signals, and pulse train inputs,
independently of the external on/off status.
1EA5
4
[0] [3] Prohibits all output devices (DO). 1EA5
[1] [0] Cancels the prohibition of the input devices except EM2, LSP
and LSN, external analog input signals and pulse train inputs.
1EA5
[1] [3] Cancels the prohibition of the output device. 1EA5
(7) Operation mode selection (command [8] [B])
Command Data No. Description Setting range
Control
mode
Frame
length
CP CL
[8] [B] [0] [0] Selecting test operation mode
0000: Test operation mode cancel
0001: JOG operation
0002: Positioning operation
0004: Output signal (DO) forced output
0005: Single-step feed operation
0000 to 0002,
0004, 0005
4

Table of Contents

Related product manuals