4. STARTUP
4 - 7
The control axis No. can be set in the range of 1 to 16 with the axis selection rotary switch.
If the same numbers are set to different control axes in a single communication system, the system will not
operate properly. The control axes may be set independently of the SSCNET III cable connection sequence.
Table 4.1 shows control axis numbers corresponding to the axis selection rotary switch to set the control axis
number.
8
7
6
5
4
3
2
1
0
F
E
D
C
B
A
9
A
xis selection rotary switch (SW1)
Table 4.1 Switch combination list for the control axis No. setting
Axis selection rotary switch (SW1) Control axis No.
0 1
1 2
2 3
3 4
4 5
5 6
6 7
7 8
8 9
9 10
A 11
B 12
C 13
D 14
E 15
F 16