Appendix 1.3 G(P).OGSTOR
Restores the offset/gain values of the user range setting stored in the CPU to the A/D
converter module.
Set data
Usable devices
Internal device
(System, user) File
register
Link direct device
J \
Intelligent
function
module
U
\G
Index
register
Z
Constant
Other
Bit Word Bit Word K, H $
(S) —
— — — —
(D)
— — — —
Command
G.OGSTOR
Command
GP.OGSTOR
Un (S) (D)
Un (S) (D)
[Instruction
symbol]
[Execution
condition]
G.OGSTOR
GP.OGSTOR
Set data
Set data Description Setting range Data type
Un Start I/O number of the module 0 to FEH Binary 16 bits
(S)
1
Start number of the device in which control data is stored.
Within the range of the
specified device
Device name
(D)
Device that is turned ON 1 scan on completion of dedicated
instruction processing.
(D) + 1 also turns ON at an abnormal completion.
Within the range of the
specified device
Bit
1 When executing the G(P).OGLOAD instruction, specify the device designated in (S).
Do not change the data read with the G(P).OGLOAD instruction.
If it is changed, normal operation cannot be guaranteed.
Control data of Q64AD-GH (1/2)
Device Item Set data Setting range Set by
(S) System area — — —
(S) + 1 Completion status
Stores the status when the
instruction is complete.
0 : Normal completion
Other than 0: Abnormal completion
— System
(S) + 2 Pass data classification setting
The value set to Pass data
classification setting (S)+2 using the
G(P).OGLOAD instruction is stored.
0: Voltage specified
1: Current specified
0 0 CH4 CH3 CH2 CH1
b15 b4b3b2b1b0
to
0000H to 000F H
System
(S) + 3 System area — — —
(S) + 4
CH1 Industrial shipment settings offset value (L)
(H)
— — System
(S) + 5
(S) + 6
CH1 Industrial shipment settings gain value (L)
(H)
— — System
(S) + 7
(S) + 8
CH2 Industrial shipment settings offset value (L)
(H)
— — System
(S) + 9
(S) + 10
CH2 Industrial shipment settings gain value (L)
(H)
— — System
(S) + 11