28
-
(2) Outdoor unit
Model SCM45ZD-S
SWITCHING
POWER CIRCUIT
P
L-1
N-1
BL
GR
BL
GR
L-OUT2
L
N
1
2
3
RD
20S
G2
Y/G
+
-
~
~
DS1
CNI
RAM DATA
U
WH
RD
BKW
CM
V
PWB ASSY(POWER) PWB2
F1
250V 20A
F1
200V 2A
EEV_B
EEV_A
Tho-D
Tho-A
Tho-R
Tho-C
1
2
3
4
5
6
7
8
HEATER
F
Power source
1 Phase
220/230/240V
250V 15A
Y/G Y/G
EARTH
1
2
3
BR
BK
BK
WH
WH
WH
1
1
2
2
CNO
CNP
CNB CNC
CND
CNJ CNK
CNG
CNI
RD
BK
P_1N_1
P_1N_3
123456 123456
12
CNN CNH
1234567891011121312345
12345 12345678910111213
FMo
CNS
CFO
1
3
7
5
CAP1
CAP2
Me
Lo
COM WH
RD
BL
BK
OR
Y
G3
AC.L
AC.N
N-OUT2
BK RD
PWB ASSY(CAPACITOR) PWB3
PWB ASSY(CPU) PWB1
NW
V
U
DC-P
DC-N
N1
L
N2
P2
BK BK
C1 C2 C3
2
1
IC12 Q11
RD
WH
BK
CNG CNH
T1
T2
T3
Unit
A
Unit
B
AF-L2 AF-L1
OR OR
L
OR OR
Black
Red
White
Yellow/Green
BK
RD
WH
Blue
Yellow
BL
Brown
BR
Gray
GR
Orange
OR
YL
Y/GN
Color symbol
NF
LED 5
ERROR
NF
NF
LED 4
Unit A
(Green)
(Red)
LED 3
Unit B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi SCM80ZD-S and is the answer not in the manual?

Mitsubishi SCM80ZD-S Specifications

General IconGeneral
BrandMitsubishi
ModelSCM80ZD-S
CategoryAir Conditioner
LanguageEnglish