Operations for running equipment and maintenance procedures.
Requires knowledge and experience for operation and maintenance of mechanical equipment.
Wear protective items such as helmet and safety footwear as required.
Unauthorized alteration or repair procedures pose serious safety risks.
Warning labels are affixed where caution is required for operation.
General safety precautions for operation and maintenance.
Safety precautions that apply specifically to the installation process.
Safety precautions that apply to the actual use of the equipment.
Precautions for moving, reselling, or re-using the equipment.
Overview of the product's purpose and capabilities.
Details the automatic determination of boilers, efficient operation, and stability features.
Illustrates the system composition: steam header, pressure sensor, and controllers.
Technical specifications of the unit.
Details applicable boilers, control pressure, communication, and functions.
Lists external control input and monitor output terminal specifications.
Identifies and explains the components of the system.
Details the components of the Pressure Controller.
Explains the LEDs, switches, and display functions of the control panel.
Details switches, potentiometers, and terminal blocks within the main unit.
Details the MI Terminal unit.
Explains the display, LEDs, and switches of the MI Terminal control panel.
Shows the internal layout, including CPU and power supply.
Procedures for operating the Pressure Controller.
Details display control by the 'DISPLAY CHANGE' switch.
Instructions for stopping and firing up boilers via external signals.
Procedures for stopping all boilers using the all stop input terminal.
Procedures for firing up all boilers using the all combustion input terminal.
Methods for setting control pressure and alarm pressure via internal potentiometers.
Setting methods for switches and pressure sensor adjustment values.
Sets the quantity of boilers to be controlled.
Sets the quantity of boilers to be held at low-fire conditions.
Procedure for adjusting pressure sensor for deviation in steam pressure display.
Procedures for operating the MI Terminal.
Describes display control by the 'SELECT' switch.
Switching boiler operation between automatic and manual modes.
Turns the timer control on or off.
Common setting operations using the 'SELECT' switch.
Determines boiler priorities for firing based on header steam pressure.
Sets the current time for the timer function.
Sets the day of the week for the timer function.
Sets cumulative time to determine boiler priorities for automatic rotation.
Describes setting operations on the basic data display mode.
Sets combustion stop pressure under manual operation.
Sets high fire stop pressure under manual operation.
Provides standby pressure under automatic operation for stable response.
Sets boiler ON and OFF times for each day of the week.
Continues low fire before stopping to prevent gas pressure fluctuation.
Sets fixed time for automatic rotation when boilers are stopped or in combustion.
Sets rotation timing identification for automatic rotation.
Notifies blowdown timing by blinking 'B.BLOW' LED.
Lists all settable and displayable items on the unit.
Fires boilers based on steam pressure and priority.
Lists statuses where boilers are not controlled by MI control.
Increases boiler quantity based on load and header steam pressure.
Assigns higher priority to boilers with shorter cumulative combustion time.
Handles backup control for boilers out of control or during pre-purge.
Determines boiler priority automatically based on cumulative combustion time.
Activates rotation after complete blowdown when flag is set to 8.
Details external control inputs for the Pressure Controller.
Explains external control input terminal blocks for emergency stop, alarm check, etc.
Describes non-voltage contact output terminals for external monitoring.
Contact closes when a pressure sensor error is detected.
Contact closes when input is provided to the emergency stop terminal.
Allows operation with an optional pressure sensor on MI Terminal.
Allows changing the pressure display unit to MPa, kgf/cm², or psi.
Troubleshooting steps for incorrect pressure indications on the controller.
Troubleshooting for boilers failing to start combustion.
Troubleshooting for automatic rotation not functioning or priorities not changing.
Lists warnings displayed on the MI Terminal and their countermeasures.
Ensures proper installation and facility confirmation for moving or reselling.
Details warranty terms, coverage, and limitations.
Instructions on how to purchase additional operation manuals.