ERROR SCENARIO:
Error codes occur E3
CHECK POINTS:
Top plate Sensor Overheat or Short Circuit
REMEDY:
Start again after the temperature cool down If not, please return the
cooker to the service center for checking and repairing
---
ERROR SCENARIO:
Error codes occur E4
CHECK POINTS:
Top Plate Sensor Open Circuit or without connect
REMEDY:
Please contact service center for checking and repairs
---
ERROR SCENARIO:
Error codes occur E5
CHECK POINTS:
IGBT Sensor Overheat or Short Circuit or Fan without connect
REMEDY:
please contact service center for checking and repairs
---
ERROR SCENARIO:
Error codes occur E6
CHECK POINTS:
IGBT Sensor Open Circuit
REMEDY:
please contact service center for checking and repairs