Do you have a question about the Mobeye CM-Guard TwinLog CML4055 and is the answer not in the manual?
Brand | Mobeye |
---|---|
Model | CM-Guard TwinLog CML4055 |
Category | Measuring Instruments |
Language | English |
Standard behavior with Mobeye SIM: alarm notifications, data logging via Internet Portal.
Standard behavior with own SIM: alarm SMS and calls to programmed numbers.
Procedure for opening the device and inserting the SIM card.
Connecting external sensors or analog devices to input ports (IN1, IN2).
Instructions for correctly inserting the device's CR123 batteries.
Optional connection of an external 12-24V DC power supply.
Connecting devices to the open collector output for alarm or SMS control.
Understanding LED indicators for network connection and program mode.
Steps to create an account and sign up for the Mobeye Internet Portal.
Activating the Mobeye SIM card and associating it with the device in the portal.
Methods for configuring settings and synchronizing them with the CML4055 device.
Overview of the portal's dashboard, status, history, and device data management.
Procedure for arming, disarming, and updating the device's operational status.
Guide to resetting the CML4055 to its original factory default configuration.
Setting up multiple phone numbers to receive alarm notifications.
Setting the frequency for regular 'keep-alive' test messages.
Specifying input behavior as Normally Open, Normally Closed, or Analog.
Establishing voltage thresholds for triggering alarms on analog inputs.
Determining the time interval between logging analog sensor readings.
Configuring the frequency for transferring logged data to the portal.
Defining a delay period before an alarm is activated upon input change.
Setting a lockout period after an alarm before new alarms are sent.
Configuring how often alarm messages are re-sent if the condition persists.
Enabling messages that confirm when an alarm state has been cleared.
Setting up notifications for power loss and power restoration events.
Delaying power failure alerts to prevent false alarms from brief outages.
Scheduling automatic arming and disarming based on time and day.
Preventing accidental changes by locking the device's physical buttons.
Defining the time between device activation and the first alarm transmission.
Customizing output signal behavior (e.g., pulse, latch) and duration.
Optimizing power consumption by managing communication module activity.
Selecting call or SMS notification preferences when using a personal SIM card.
Steps to enter the program mode for receiving SMS configuration commands.
How to format and send SMS messages to configure device settings.
Configuring at least one mandatory phone number for alarm and system messages.
Detailed reference of SMS commands, options, and default values for configuration.
Procedures for arming/disarming the device using SMS commands or the physical button.
Steps to perform a factory reset using the device's button.
How to retrieve device status, settings, and phone lists via SMS queries.
Understanding technical alerts related to power, batteries, and network issues.
Guide to understanding device status based on LED flash patterns and required actions.
Details on communication protocols, power consumption, and battery life.
Device size, weight, and operating temperature range.
Information on compliance with EU directives for safety, EMC, and radio equipment.