EasyManua.ls Logo

Moeller DF6-340 Series - Fault Messages; State of Frequency Inverter on Fault Message

Moeller DF6-340 Series
18 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Quick Reference Guide
DF6 Frequency Inverter
02/02 AWB8230-1449GB
4
Fault messages
When an overcurrent, overvoltage or undervoltage occurs, the
output of the DF6 frequency inverter is disabled to protect the DF6
from damage. The connected motor then coasts to a stop. The
inverter remains in this condition until the fault message is
acknowledged with the OFF key or the RST input.
State of frequency inverter on fault message
The frequency inverter’s state when a fault occurs provides
additional information to help rectify the fault.
Some fault messages indicate the status of the DF6 frequency
inverter with a number after the point. E07.2, for example,
means that fault 7 has occurred while the frequency inverter was
in status 2.
The individual states are described in the table below
Status code DF6 status
---.0 Reset
---.1
Stop
---.2
Deceleration
---.3
Static operation
---.4
Acceleration
---.5
f
0
stop
---.6
Start
---.7
DC braking
---.8
Current limit
---.9
Autotuning