EasyManua.ls Logo

Moeller DF6-340 Series - Deceleration Time; Direction of Rotation; PNU Name Adjustable in RUN Mode Value; Normal Extended

Moeller DF6-340 Series
184 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Setting Parameters
01/02 AWB8230-1413GB
106
Deceleration time 1
Deceleration time 1 defines the time in which the motor brakes to
0 Hz after a stop signal.
Direction of rotation
The direction of rotation defines the direction in which the motor
turns after a start signal is issued.
PNU Name Adjustable in RUN mode Value Function WE
Normal Extended
F003
F203
Deceleration
time 1
j j 0.1 to 3600 s Resolution of 0.01 s at an input of 0.01 to 99.99
Resolution of 0.1 s at 100.0 to 999.9
Resolution of 1 s at an input of 1000 to 3600
30.0
PNU Name Adjustable in RUN mode Value Function WE
Normal Extended
F004 Direction of
rotation
00 The motor runs in a clockwise direction. 00
01 The motor runs in an anticlockwise direction.
efesotomasyon.com - Klockner Moeller - inverter

Table of Contents

Other manuals for Moeller DF6-340 Series

Related product manuals