Appendix
01/02 AWB8230-1413GB
162
Safety features Overcurrent
Overvoltage
Undervoltage
Overtemperature
Earth fault
Overload
Electronic motor protection
Current transformer fault
Dynamic braking function (regenerative)
Ambient conditions
Ambient temperature –10 to +40 °C
Temperature/humidity during storage
–25 to 65 °C (for short periods only, e.g. during transport)
20 to 90 % relative humidity (non condensing)
Permissible vibration
Up to 5.9 m/s
2
(= 0.6 g) at 10 to 55 Hz Up to 2.94 m/s
2
(= 0.3 g) at 10 to 55 Hz
Installation height and location
Up to 1000 m above sea level in a housing or control panel (IP54 or similar)
Optional accessories
Remote operating unit: DEX-KEY-10
Choke to improve the power factor
RFI filter: DE6-LZ...-V4
Expansion modules
–Encoder module: DE6-IOM-ENC
–PROFIBUS-DP module: DE6-NET-DP
DF6-340-...
11K 15K 18K5 22K 30K 37K 45K 55K 75K 90K 110K 132K