MOHAWK MODEL LMF-12, TP-15 ,TP-16 & TP-18
ii
APPENDAGE:
Rev (2/9/2006)
LIFT ENVIRONMENT:
All standard lifts are designed for indoor usage in a normal garage type environment. Any concerns in
applications that expose the lift to additional environmental effects, such as paint booths, wash bays,
outdoors, high or low temperatures, etc. must be addressed to our engineering department, where
provisions may be made to the lift to accommodate the area of use. Our engineering department must be
made aware in advance of these conditions and any additional code requirements that must be met.
Also, the foundation for which this lift must be installed on must comply to the minimum specifications
as set forth in this manual. Any drainage slopes in the bay where the lift is to be installed must be
directed away from the posts to prevent water accumulation at the post bases.
ACCESSORIES:
All accessories (i.e. Lifting Pads, Height Adapters, Wheel Adapters, Turf Adapters) supplied with this
lift are to be used on this lift only. Accessories from other lifts are not acceptable and could result in
injury to the user.
If attachments, accessories or configuration modifying components are used on this lift and, if they are
not certified for use on this lift, then the certification of this lift shall become null and void. Contact the
participant (Mohawk Resources Ltd.) for information pertaining to certified attachments, accessories or
configuration modifying components.
LOCK WARNING:
Latches do not automatically reset after disengagement. After the latches have been manually
disengaged, this lift must be raised approximately 2 inches to reactivate the latches.
LOCKOUT/TAGOUT REQUIREMENTS:
The start switch provided with this unit must not be used as a primary disconnecting means. A separate
disconnecting means must be provided in accordance with all applicable codes. It is the responsibility of
the owner/user of this unit to provide a proper lockout/tagout device for this unit before or during
installation in conformance to ANSI Z244.1 and any local/state/national electrical codes and any OSHA
regulations.
PROPER SELECTION OF POWER SUPPLY CORD:
Acceptable Cord Types: SO, SEO,STO, SOW, SEOO, SOW-A
Cord Size: 12/4
Cord Ampacity: 20 Amps
Cord Wiring: Use Female NEMA Plug supplied with lift and wire as follows (See Diagram Below),
G: Ground (green)
W: Neutral (white)
X: 208 VAC Hot, 110 VAC to ground (Red)
Y: 208 VAC Hot, 110 VAC to ground (Black)
Face of Plug Represented: