Things you can do to prevent this freeze up are:
1. Ensure the LP tank is totally free of moisture prior to filling.
2. Ensure the tank is not overfilled.
3. Keep the valve closed when the tank is empty.
4. A LP-Gas dealer will need to purge the tank if freeze up occurs.
5. Have the LP-Gas dealer inject methyl alcohol in the tank.
WARNING: Do not attempt to adjust the regulator, it is preset
at the factory. If adjustments need to be made it requires spe-
cial equipment. Failure to follow these instructions may result
in a fire or explosion and cause severe personal injury or
death. DO NOT ATTEMPT TO REENTER THE
MOTORHOME UNTIL THE PROBLEM HAS BEEN
CORRECTED!
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
• Manually open the main shutoff valve located on the
roadside of the LP tank.
• Turn off the manual valve on the LP tank when the
motorhome is between trips.
• Hand tighten the manual valve. Do not use a wrench or
pliers to close the valve.
• The manual valve is designed to be closed by hand, over
tightening may permanently damage the valve seat.
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Tank Measurement - To measure level of a tank simply push button
on display panel corresponding to tank you wish to measure. Lights on
panel will turn on in sequence indicating level of tank.
Calibration - The monitoring panel comes factory calibrated for
accuracy and should not need to be adjusted. If system does not read
accurately recalibration may be necessary.
Water & LP-Gas Systems
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
EXECUTIVE 4•126
LP TANK -
Operating & Monitoring
Monitor Panel Measurement
& Calibration
LP Tank Gauge
Shutoff Valve.