EasyManuals Logo

Monarch Nova-Strobe BBX Replacement Guide

Monarch Nova-Strobe BBX
2 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
15 Columbia Drive Amherst, New Hampshire USA 03031-2334
TEL: 603-883-3390 FAX: 603-886-3300 www.monarchinstrument.com sales@monarchinstrument.com
the professional’s choice
Nova-Strobe Battery Replacement
for models: Nova-Strobe BBX, Nova-Strobe DBX, and Phaser Strobe PBX, Vibration Strobe VBX
Taking the unit apart is the easy part . . .
To do this, [A] remove the lens by
separating the two tabs that hold
it in place. Put a piece of tape on
the side of the lens that faces out
so it can be installed correctly. Slide
the re ector [B] and lamp out as
detailed in the Lamp Replacement
section of your manual. This will
expose four screws [C] that must
be removed so the re ector hous-
ing can be removed from the main
body. There are then four additional
screws [D1] & [D2] in the case
halves opposite the input and
output jacks that must be removed.
The case halves can now be separated,
exposing the batteries. They should
be sent to a recycling center or
returned to Monarch for disposal.
Before you open the case, know that during the reassembly there are multiple points that
need to align correctly to close the case securely.
Some of them include:
Display board sits in groove
DC Connector spans both case halves
Mounting T-nut sits in slot as shown
Lanyard knot surrounds screw standoff and protrudes through the notch in the case
Trigger sits in case brackets with wires tucked out of the way
PCB aligns in a retaining groove
Battery holders (2) nests in brackets, there is a right and wrong way to insert them
[A]
[B]
[C]
[D1]
[D2]

Other manuals for Monarch Nova-Strobe BBX

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Monarch Nova-Strobe BBX and is the answer not in the manual?

Monarch Nova-Strobe BBX Specifications

General IconGeneral
Flash Duration10 to 30 μsec typical
Accuracy±0.01%
Light SourceXenon
Power115/230 Vac, 50/60 Hz
Operating Temperature32 to 104°F (0 to 40°C)