3. Procedure
A. Toilet Assembly
(1) Support the toilet tank drain outlet over a suitable waste receptacle or drain.
WARNING: A FACE GUARD AND GLOVES SHOULD BE WORN
DURING ALL STEAM CLEANING FOR PROTECTION
FROM SPLASHBACK.
(2) Clean the external and internal surfaces of the bowl assembly using either a
solution of hot, soapy water and strong disinfectant or a steam cleaner.
(3) Remove the bowl assembly and the separator assembly (refer to
DISASSEMBLY).
(4) Open the drain valve to the fully compressed position by pulling on the valve
cable assembly and clamp or otherwise secure the cable assembly in this
position. Do not crimp the cable.
CAUTION: EXERCISE CARE TO AVOID PROLONGED APPLICATION
OF STEAM TO ANY PLASTIC SURFACES.
(5) Steam clean all interior surfaces of the tank, back flush through the flushing
motor pump outlet channel, which is exposed when the bowl is removed, and
through the vent and flushing openings.
(6) Drain all liquid from the tank assembly.
(7) Dry all surfaces of the tank and internal components with dry, compressed air.
CAUTION: DO NOT USE HYDROCARBON SOLVENTS, CHEMICAL
SOLVENTS OF THE ETHER OR FLUORIDE FAMILY,
ACETONE, METHYL- ETHYL-KETONE, OR RELATED
SOLVENTS ON ANY KEVLAR OR PLASTIC PARTS. DO
NOT USE ABRASIVE OR SCOURING CLEANSER ON
ANY METAL, FIBERGLASS OR PLASTIC PARTS.
(8) If additional cleaning of subassemblies and detail parts is required after removal
from the tank assembly, use a soap, disinfectant, and hot water solution and a
stiff-bristled brush.