EasyManua.ls Logo

Monzana MZKA780 User Manual

Monzana MZKA780
85 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
www.DEUBAXXL.de
BDA-108934
-001/108935
-001
DE EN FR ES

Questions and Answers:

Monzana MZKA780 Specifications

General IconGeneral
BrandMonzana
ModelMZKA780
CategoryAir Conditioner
LanguageEnglish

Summary

Symbols

Product Modification Warning

Warns against modifying the product, invalidating warranty and causing danger.

Electrical Voltage Safety

Emphasizes that electrical work must be done by authorized specialists.

Risk of Suffocation

Advises keeping small parts away from children and checking for damage.

Safety Instructions on the Unit

Room Size Requirement

The unit must be installed, operated, and stored in a room with a floor area larger than 8 m².

Staff Qualification for Operation

Details user qualifications, age limits, and supervision requirements for operating the unit.

Staff Qualification for Maintenance

Outlines the necessary qualifications for individuals performing maintenance and repair work.

Units – Safety Instructions

Refrigerant Safety

Covers handling of R290 refrigerant, leak detection, and ignition source avoidance.

Safety Precautions During Maintenance and Repair

No User Repairable Components

States that the unit contains no user-serviceable parts; refrigerant circuit is sealed.

Residual Risks

Natural Refrigerant (R290) Hazards

Details hazards of R290, including flammability and pressure risks.

Operational Precautions

Power Connection and Cord Safety

Details on connecting to power, using earthed sockets, and safe cord handling.

Safe Operating Practices

Guidelines on avoiding water exposure, unattended use, and proper plug removal.

Physical Handling and Placement Rules

Prohibits placing items on the unit, climbing, inserting objects, or touching sensitive parts.

General Operational Safety

Covers using undamaged units, avoiding chemical cleaning, and fire safety.

Further Operational & Storage Guidelines

Installation and Cleaning Agents

Guidelines for installation according to regulations and using approved cleaning agents.

Storage Conditions

Requirements for storing the unit safely, avoiding damage, heat, and ensuring ventilation.

Intended Use

Product Purpose and Limitations

Defines the product's purpose, functions, and limitations (domestic use only).

Commissioning

Product Image and Components

Illustrates the unit and labels its key components for identification.

Unit Properties and Functions

Details the main features, such as cooling, heating, dehumidification, and timer functions.

Unpacking Instructions

Step-by-step guide for removing the unit and accessories from the packaging.

Selecting a Location

Criteria and considerations for choosing an appropriate installation site for optimal performance.

Connecting the Exhaust Air Hose

Instructions on how to connect the exhaust hose to vent hot air outside the room.

Operation

Control Panel and Display Overview

Identifies and explains the functions of the unit's control panel buttons and display elements.

Switching On and Off

Instructions for powering the unit on and off.

Operating Modes

Details the five operating modes: cooling, drying, ventilation, heating, and energy-saving.

Timer Setting

Instructions on how to set the timer for automatic operation within a 24-hour period.

Automatic Defrosting

Explains how the unit automatically defrosts to maintain performance in low temperatures.

Tuya App Control (Optional)

Guide for connecting and using the smartphone app to control the unit.

Overload Protection

Details the unit's protection against compressor damage during power failures.

Condensate Drainage System

Explains the automatic evaporation system and manual drainage procedures.

Cleaning and Care Instructions

Air Filter Cleaning

Procedures for cleaning the air filter every two weeks to ensure efficient operation.

Decommissioning and Storage

Storage Procedures

Instructions for cleaning, drying, and storing the unit for long-term periods.

Transport Guidelines

Precautions and steps for moving the unit safely to prevent damage.

Troubleshooting Common Issues

A guide to identifying and resolving problems encountered during operation.

Technical Data

Model Specifications

Provides comprehensive specifications including model, capacity, power, and dimensions.

Maintenance by Specialist Staff

Work Area Safety Checks

Emphasizes safety tests, controlled work environment, and checking for flammable gases.

Refrigerant Testing and Fire Safety

Covers testing for refrigerant presence and ensuring fire extinguisher availability.

Ignition Source Prevention

Strict rules against using any ignition sources in the work area.

Ventilated Room Requirements

Ensures adequate ventilation during any work on the unit.

Unit Testing Procedures

Outlines tests for parts, filling amount, and markings for systems with flammable refrigerants.

Electronic Verification and Safety Checks

Initial safety tests for electrical parts, including discharging condensers and earth connection checks.

Disposal

Correct Product Disposal

Instructions for disposing of electronic devices responsibly, not in household waste.

Battery Disposal and Symbols

Information on returning used batteries and the meaning of battery recycling symbols.

Related product manuals