AIR COMPRESSOR
MANUAL
TROUBLESHOOTING
A. Typically, the above noted issue is indicative of an air leak. At each of the connections mentioned
below, it is advised to use a soapy water leak test to determine whether air is leaking from a
connection. ALL threaded and push-to-connect connections should be thoroughly tested with a
soap and water solution to appropriately find or rule out a leak.
B. Turn the brass wing nut (located at the bottom of the compressor tank) in the counterclockwise
direction until tight to ensure that no air is escaping from the tank. Use the soapy water test to ensure
no air is escaping.
C. If the wing nut is found to be tight, check the threaded hose connection at the compressor and at the
tank to ensure that connections are appropriately seated and tight. Use the soapy water test to ensure
no air is escaping.
D. Visually inspect the braided hose to ensure it is not kinked.
E. Check the push-to-connect hose connections on the output side of the tank to ensure the hoses are
properly and completely seated into the connections. Use the soapy water test to ensure that no air is
escaping at any of these connections.
F. If it is determined that all connections on the compressor are appropriately seated and determined to
be leak free via a thorough soapy water test, contact your dealer or MORryde for further support.
COMPRESSOR CONTINUALLY RUNS, AND TANK DOES NOT BUILD PRESSURE