OPERATION
CHARGING YOUR BATTERY
1. Follow the instructions in the Connecting
Your Battery section to connect your battery,
and then connect the charger to a live AC
electrical outlet.
2. Upon power-up, the default selection for
charge rate will be Boost Charge. If this is
not preferred, choose the 6 A rate.
3. Press the Start/Stop button to begin charging
immediately. If the Start button is not pressed
within 30 seconds after power-up, and a
battery is properly connected, the charging
process will begin automatically.
4. When charging is complete,
a. Or if done charging, press the Stop
button, disconnect the charger from AC
power, and disconnect the battery clamps
following the instructions for disconnection
in the Connecting Your Battery section.
b. To keep the battery in maintain mode, do
not press the Stop button, and leave all
connections. For more information, see
the Maintain Mode section.
BATTERY CHARGING TIMES
Ah – Amp Hour
CCA – Cold Cranking Amps
RC – Reserve Capacity
NR – Not Recommended
BATTERY SIZE/RATING
6 A
CHARGE
40 A<>15 A
BOOST
CHARGE
Small Batteries
25-32 Ah 1¼-3¼ h NR
Cars
and
Trucks
200-315 CCA 40-60 RC 3¾-4¾ h 1-1¼ h
315-550 CCA 60-85 RC 4¾-6 h 1¼-1½ h
550-1000 CCA 85-190 RC 6-11½ h 1½-3¼ h
Marine/Deep-Cycle
80 RC 6 h 1½ h
140 RC 9 h 2¼ h
160 RC 10 h 2½ h
180 RC 11 h 2¾ h
Times are based on a 50% discharged battery and may
change, depending on age and condition of battery.
ABORTED CHARGE
If charging cannot be completed normally,
charging will abort. When charging aborts, the
charger’s output is shut off and the Red LED will
blink. To reset after an aborted charge, unplug the
charger from the AC outlet, wait a few moments
and then plug it back in.