EasyManua.ls Logo

Motorola Canopy - Figure 8: Detail of Pole Mounting

Motorola Canopy
49 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AP_CMM2 User Manual Pa
g
e 27 of 49
- The modules can be mounted in a variety of locations, choose the best location
for your particular application. Modules do not have to mounted directly next to
each other, they can be distributed throughout a given site. Mounting can be done
by using stainless steel hose clamps or another equivalent fastener.
Mount the Cluster Management Module
- Mount the module in a location that will allow access for service if necessary.
- The farthest that the Access Point modules can be from the
Cluster Management Module is 328 feet (100 meters).
- The module should not be mounted closer than 10 feet (3 meters) to the Access
Point modules or Backhaul Modules
- The module box has flanges for ease of installation. Hardware is included to
support different mounting options:
- Directly to a wall (screws or bolts not included)
- Around irregular shaped objects (via adjustable stainless steel bands,
included)
- To a pole with an outside diameter of 1.25 to 3.00 inches
(approximately 3 to 8 cm). (toothed V brackets, included).
Figure 8: Detail of pole mounting
Mount the GPS antenna
- The GPS antenna must be located so that it has an unobstructed view of the sky (20-
degrees off the horizon) and is not the highest item at the installation site (for
lightning).
- The GPS antenna mount is provided with U-bolts for pole sizes of 1.25 to 1.50 inches
(approximately 3 to 4 cm).

Table of Contents