11 - 2 DS3508 Product Reference Guide
Errors While Scanning
Unless otherwise specified, to correct an error during a scanning sequence, just re-scan the correct parameter.
Symbology Parameter Defaults
Table 11-1 lists the defaults for all symbologies parameters. To change the default values, scan the appropriate bar
codes in this guide. These new values replace the standard default values in memory. To recall the default
parameter values, scan the Set Default Parameter on page 4-5.
NOTE See Appendix A, Standard Default Parameters for all user preferences, hosts, and miscellaneous default
parameters.
Table 11-1
Parameter Defaults
Parameter
Parameter
Number
Default
Page
Number
UPC/EAN
UPC-A 01h Enable 11-7
UPC-E 02h Enable 11-7
UPC-E1 0Ch Disable 11-8
EAN-8/JAN 8 04h Enable 11-8
EAN-13/JAN 13 03h Enable 11-9
Bookland EAN 53h Disable 11-9
Decode UPC/EAN/JAN Supplementals (2 and 5 digits) 10h Ignore 11-11
User-Programmable Supplementals
Supplemental 1:
Supplemental 2:
F1h 43h
F1h 44h
11-13
UPC/EAN/JAN Supplemental Redundancy 50h 10 11-13
Decode UPC/EAN/JAN Supplemental AIM ID F1h A0h Combined 11-14
Transmit UPC-A Check Digit 28h Enable 11-14
Transmit UPC-E Check Digit 29h Enable 11-14
Transmit UPC-E1 Check Digit 2Ah Enable 11-15
UPC-A Preamble 22h System Character 11-16
UPC-E Preamble 23h System Character 11-16
UPC-E1 Preamble 24h System Character 11-18
Convert UPC-E to A 25h Disable 11-19