98-08901C68-O 195
AT Commands Reference
The following table shows the S102 parameters.
Example
ATS102? <enter>
030
OK
ATS102=100 <enter>
OK
ATS102? <enter>
100
OK
(This means if there is data for transmission to the terminal, the g20 drops the Wakeup Out line, waits 100 ms. and then sends
data to the terminal.)
4.10.2.5 +MSCTS, Enable/Disable CTS During Wakeup Period
This command defines the behavior of the CTS line when the g20 is in normal mode (not Sleep mode).
The command configures the g20 CTS line behavior always to follow the flow control requirements, or to follow it only if the
terminal initiated a serial transmission session. This saves the terminal from following the CTS interrupt every time the g20 exits
Sleep mode for internal g20 reasons (non-terminal communication related reasons).
Set Command
The Set command tells the g20 whether to activate the CTS when the unit is awakening.
Read Command
The Read command returns the current control value.
Table 93. S102 Parameters
<Parameter> Description
<value> 0 <= value <= 255
The default value is 30 ms.
Command Response/Action
AT+MSCTS=<control> OK
Command Response/Action
AT+MSCTS? +MSCTS: <current control>
OK