2-6 Pre-baking of Integrated Circuits
5.1 IPC/JEDEC J-STD-020D.1 (March 2008) Chart
Table 2-4 Moisture Sensitivity Levels
LEVEL
FLOOR LIFE
SOAK REQUIREMENTS
STANDARD
ACCELERATED EQUIVALENT
1
Note 1: CAUTION To use the “accelerated equivalent” soak conditions, correlation of damage response (including
electrical, after soak and reflow), should be established with the “standard” soak conditions. Alternatively, if the
known activation energy for moisture diffusion of the package materials is in the range of 0.40–0.48 eV or 0.30–0.39
eV, the “accelerated equivalent” may be used. Accelerated soak times may vary due to material properties (e.g. mold
compound, encapsulant, etc.). JEDEC document JESD22-A120 provides a method for determining the diffusion
coefficient.
eV
0.40–0.48
eV
0.30–0.39
CONDITION
TIME
(hours)
CONDITION
TIME
(hours)
CONDITION
TIME
(hours)
TIME
(hours)
1 Unlimited
30 °C/85%
RH
168
+5/-0
85 °C/85%
RH
NA NA NA
21 year
30 °C/60%
RH
168
+5/-0
85 °C/60%
RH
NA NA NA
2a 4 weeks
30 °C/60%
RH
696
2
+5/-0
Note 2: The standard soak time includes a default value of 24 hours for semiconductor Manufacturer’s Exposure Time
(MET) between bake and bag and includes the maximum time allowed out of the bag at the distributor’s facility.
If the actual MET is less than 24 hours, the soak time may be reduced. For soak conditions of 30 °C/60% RH, the
soak time is reduced by 1 hour for each hour the MET is less than 24 hours. For soak conditions of 60 °C/60% RH,
the soak time is reduced by 1 hour for each 5 hours the MET is less than 24 hours.
If the actual MET is greater than 24 hours the soak time must be increased. If soak conditions are 30 °C/60% RH,
the soak time is increased 1 hour for each hour that the actual MET exceeds 24 hours. If soak conditions are
60 °C/60% RH, the soak time is increased 1 hour for each 5 hours that the actual MET exceeds 24 hours.
Note 3: Supplier may extend the soak times at their own risk.
30 °C/60%
RH
120
+1/-0
168
+1/-0
60 °C/60%
RH
3 168 hours
30 °C/60%
RH
192
2
+5/-0
30 °C/60%
RH
40
+1/-0
52
+1/-0
60 °C/60%
RH
4 72 hours
30 °C/60%
RH
96
2
+2/-0
30 °C/60%
RH
20
+5/-0
24
+0.5/-0
60 °C/60%
RH
5 48 hours
30 °C/60%
RH
72
2
+2/-0
30 °C/60%
RH
15
+5/-0
20
+0.5/-0
60 °C/60%
RH
5a 24 hours
30 °C/60%
RH
48
2
+2/-0
30 °C/60%
RH
10
+0.5/-0
13
+0.5/-0
60 °C/60%
RH
6
Time on
Label (TOL)
30 °C/60%
RH
TOL
30 °C/60%
RH
NA NA NA