Figure 67: Modem FRU Product Label
MAC 1:
AABBCCDDEEFF
MAC 2:
AABBCCDDEEFF
SN:
I.T.E.
31 NH
Serial No: XXXXXXXXX
Model No: XXXXXXXXXXXXXX
S/Tanapa: XXXXXXXXXXXXXX
FCC ID: XXXXXXXXXXX
IC: XXXXX-XXXXXXXX
IC Model No: XXX XXXX-XXXX
100-240V ~ Max 4A 50/60 Hz
11.0-14.4V 17A Max
This device complies
with Part 15 of the
FCC rules. Operation is
subject to the condition
that this device does not
cause harmful interference
SLR 5700
11.6.1.5
Power Supply Installation
Procedure:
1 Place the Power Supply Module into the repeater chassis until the back of the power supply
rests against back panel.
Figure 68: Installing Power Supply Module
2 Take the Chassis ID Module (PN: 84009669001) and insert chassis ID cable end into the 8 pin
connector on the Modem. Route Chassis ID Module cable underneath power supply cables.
3 Tighten the four M4 x 0.7 x 10 mm screws (PN: 0310909A61) to 15 in-lb (1.7 N-m) using a T20
Torx driver to secure the Power Supply Module to the repeater chassis.
Chapter 11: SLR 5000 Series Maintenance and Disassembly/Reassembly
Motorola Solutions Confidential
106 Send Feedback