TEST SETUP & TESTING 380–430MHz MTP850 TETRA Handportable Terminal / Basic Service Manual 5.1 - 3
Test Check List
The following table summarises the required test setups.
No. Test Name Test Setup Radio Setup
Test
Conditions
Limits
1. Base Station
Registration
Control
Channel
390.125 MHz 3605 TETRA 380+0MS
Traffic
Channel
390.125 MHz 3605 TETRA 380+0MS
Time Slot 3
Country
Code
234
Network
Code
2392
Base Color 1
Location
Area
23
Min Rx Level -110dBm
Max Tx Level 30dBm (1W radio)
32.5dBm (1.8W radio)
Access
Parameter
-53dBm
Mobile
Power
30dBm (1W radio)
32.5dBm (1.8W radio)
Burst Type Normal
2. Transmitter
Burst Power
RF Gen
Level Burst
Power
-90dBm 28–32dBm (1W radio)
30.5–34.5dBm (1.8W
radio)
Timing Error <=0.25 Symbols
Vector Error Max 10% RMS, 30% Peak
Frequency
Error
± 100Hz
3. Call Processing
Talk Back
1KHz Test
Signal Group
Mode
-50dBm
4. Call Processing
Call to Mobile