EasyManua.ls Logo

Motorola MVME2400 Series - Page 148

Motorola MVME2400 Series
175 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
C-4 Computer Group Literature Center Web Site
Troubleshooting
C
IV.
Continued
2. At the command line prompt, type in:
env;d <CR>
This sets up the default parameters for the
debugger environment.
3. When prompted to Update Non-Volatile RAM,
type in:
y <CR>
4. When prompted to Reset Local System, type in:
y <CR>
5. After clock speed is displayed, immediately
(within five seconds) press the Return key:
<CR>
or
BREAK
to exit to the System Menu. Then enter a 3 for
“Go to System Debugger” and Return:
3 <CR>
Now the prompt should be:
PPC1-Diag>
6. You may need to use the cnfg command (see
your board Debugger Manual) to change clock
speed and/or Ethernet Address, and then later
return to:
env <CR>
and step 3.
7. Run the self-tests by typing in:
st <CR>
The tests take as much as 10 minutes, depending
on RAM size. They are complete when the
prompt returns. (The onboard self-test is a
valuable tool in isolating defects.)
8. The system may indicate that it has passed all the
self-tests. Or, it may indicate a test that failed. If
neither happens, enter:
de <CR>
Any errors should now be displayed. If there are
any errors, go to step VI. If there are no errors, go
to step V.
Table C-1. Troubleshooting MVME240x Modules (Continued)
Condition Possible Problem Try This:

Table of Contents