18
6802982C85-C
PARAMETER DESCRIPTION AVAILABLE OPTIONS FACTORY
SETTING
ROTARY KNOB
DEFAULT
FUNCTION
Defines the rotary knob function when
scrolling left or right.
BRIGTHNESS / VOLUME
/OSD MENU/
BRIGTHNESS & VOLUME
*
BRIGTHNESS
KEY
ILLUMINATION
CONTROL
Enable or disable illumination of
function and emergency keys.
When disabled, keys illumination is off;
when enabled, keys illumination
behaves according to selection of the
TYPE of ILLUMINATION parameter.
ENABLE / DISABLE ENABLE
LABEL
ILLUMINATION
CONTROL
Enable or disable illumination of
labels.
When disabled, illumination of labels is
off; when enabled, illumination of
labels behaves according to selection
of the TYPE of ILLUMINATION
parameter.
ENABLE / DISABLE ENABLE
TYPE OF
ILLUMINATION
Auto means illumination level of
labels, function and emergency keys is
correlated with the LCD brightness.
Manual means a constant level of
LED's, labels, function and emergency
keys illumination.
AUTO / MANUAL AUTO
MANUAL
ILLUMINATION
LEVEL
When Manual type is selected, this
parameter defines a constant level of
LED's, labels, function and emergency
keys illumination.
Control range from 0 to
100%
50%
BRIGHTNESS
FACTOR
Defines relative brightness level,
which cannot be exceeded by this
display.
Control range from 50 to
100%
100%
* When BRIGTHNESS & VOLUME is selected, the rotary knob by default controls the brightness
level. Short push will switch the rotary knob to control volume.
In addition, the display's codeplug presents read-only information such as:
Inverter Type
Display Model
Date of Manufacturing
Bluetooth Media Access Control address
Serial Number
Main board ID
Function board ID
Display Configuration Change
This section describes the software configuration tool and the most common method to
change the display configuration parameters.
Maintenance Programming Software
The Maintenance Programming Software allows modifying display configuration that starts
when you turn the display on. Use the MPS context-sensitive on-line help information for
assistance in configuring the device.