6802982C85-C
excessive drain
POWER CONSUMPTION @ 13.8 VDC max
• Maximal HB – 2.8A, SB – 1.5A (w/o heater), 4.5A (with heater)
• Standby 0.4A
ELECTRICAL TRANSIENTS Operational Electrical Transients Per ISO7637 (CE).
SAFETY Operational Safety Per UL 60950-1, EN60950-1
STORAGE CONDITIONS Temperature: -40 to 158˚F (-40 to +70˚C)
OPERATING CONDITIONS Temperature: -22 to 158˚F (-30 to +70˚C) with controlled brightness
Humidity: 90 to 95% Relative humidity at 50˚C for 8 hours
THERMAL SHOCK -40 to 158˚F (-40 to +70˚C)
MECHANICAL SHOCK 20G peak 1/2 sine wave @ 11ms, 30 impacts
VIBRATION MIL-STD-810F Method 514.5 category 4 Fig. 514.5c-1 1 hour axis.
IP RATING FOR
DUST/WATER
IP 54
DRIP Per MIL-STD 810F method 506.4 procedure III
DUST BLOWING 5 hours in dust (140 mesh silica flour), laden atmosphere, dust agitation time
is for 2 seconds every 15 minutes
SALT FOG 8 hours, 5% Sodium Chloride at 35˚C per MIL-STD-810F 509.4, procedure I
FLAMMABILITY UL94-V0
SOLAR RADIATION 7 cycles of 24 hours with no functional degradation per MIL-STD-810F,
505.4, Procedure I
IMPACT Ball drop test 130gr. Steel ball from 0.5 m height.
SHOCK CRASH HAZARD 75G, 6 ms per MIL-STD-810F method 516.5, Procedure V
ALTERNATOR WHINE: Per Motorola’s 12M05049A04
REVERSE POLARITY Per Motorola’s 12M05049A04
CRANKING Per Motorola’s 12M05049A04
ESD Per Motorola’s 12M05049A04 ESD Procedure
RADIATED IMMUNITY 20V/m EN 61000-4-3
Regulations
TEST STANDARD
eMARK Directive 72/245EC (94/95EC)
EMC IMMUNITY
• USA - EN301-489, receive full EMC certification relevant to mobile
computing device
• Canada - ICES003 (equivalent to FCC Part 15, Class B)
• Europe – CE EN55024
RADIATED EMISSION
• USA - FCC Part 15 class B #247, BQB qualification for Bluetooth
• Canada - RSS210, RSS119, RSS 132, RSS133
• Europe – CE EN55022
• Australia - AS/NZS 3548
SAFETY
• USA - UL
• Canada - UL
• Europe - EN60950