EasyManua.ls Logo

Motorola PTP 54500 - EMC Immunity Compliance

Motorola PTP 54500
228 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
17 Specifications
219
17.4 EMC Immunity Compliance
Top-level Specification ETSI 301-489.
Specication Comment
EN 55082-1 Generic EMC and EMI
requirements for Europe
EN 61000-4-2: 1995 Electro Static
Discharge (ESD), Class 2, 8 kV air, 4 kV
contact discharge
Testing will be performed to ensure
immunity to 15kV air and 8kV contact
EN 61000-4-3: 1995 ENV50140: 1993
(radiated immunity) 3 V/m
EN 61000-4-4: 1995 (Bursts/Transients),
Class 4, 4 kV level (power lines AC & DC)
Signal lines @ 0.5 kV open circuit voltage.
EN 6100045:1995, (Surge Immunity)
Requires screened connection to users
network
EN 61000-4-6: 1996 (Injected RF), power
line, Class 3 @ 10 V/m
Signal lines, Class 3 @ 3 V RMS un-
modulated.

Table of Contents