24 RS507 Hands-Free Imager
Finger Strap Replacement (Triggerless Strap Holder)
Removal
Remove the Finger Strap from the Strap
Buckles.
Installation
Slip the Finger Strap through the Strap
Buckles.
Strap Buckle
Replacement
Removal
1. Remove the Trigger Swivel
Assembly (See Trigger Swivel
Assembly Replacement on page
21).
2. Press the Strap Buckle out of the
Strap Buckle Pin.
Installation
1. Align the pin slot of the Strap Buckle with the Strap Buckle Pin.
2. Gently, press the pin slot of the Strap Buckle to engage with the Strap Buckle
Pin. The pin slot snaps onto the Strap Buckle Pin.
3. Install the Trigger Swivel Assembly (See Trigger Swivel Assembly
Replacement on page 21).
Cleaning
Wipe the exit window periodically with a lens tissue or other material suitable for
cleaning eyeglasses.
The gold plated battery contacts do not tarnish or oxidize. No maintenance should
be needed. If the contacts need to be cleaned:
CAUTION Do not pour, spray, or spill any liquid on the Imager.
Strap Buckles
Triggerless Strap Holder
Strap
Buckle
Strap Buckle Pin
Trigger Swivel Assembly