Parameter details and factory setting
( Firmware version : MDC_New_F7_176_V2.00.4 )
Preset # Parameter Adderss
Factory
setting
Fastening
1
TC/AM_AC/TM 1 0
Torque 2 Auto
Torque min/max (%) 3 0
Target angle(degree) 4 0
Min angle(degree) 5 0
Max angle(degree) 6 0
Snug torque(%) 7 0
Speed (rpm) 8 Auto
Free fastening angle(degree) 9 0
Free fastening speed(rpm) 10 0
Soft start(1-300ms) 11 0
Seating point (%) 10-90 12 Auto
Torque rising rate(ms) 50-200 13 50
Ramp up speed(rpm) 20-80% of max 14 Auto
Torque compensation (%) 90-110 15 100
2
TC/AM_AC/TM 16 0
Torque 17 Auto
Torque min/max (%) 18 0
Target angle(degree) 19 0
Min angle(degree) 20 0
Max angle(degree) 21 0
Snug torque(%) 22 0
Speed (rpm) 23 Auto
Free fastening angle(degree) 24 0
Free fastening speed(rpm) 25 0
Soft start(1-300ms) 26 0
Seating point (%) 10-90 27 Auto
Torque rising rate(ms) 50-200 28 50
Ramp up speed(rpm) 20-80% of max 29 Auto
Torque compensation (%) 90-110 30 100
3 TC/AM_AC/TM 31 0
mountztorque.com - 1080 N 11th St, San Jose CA 95112 - 408.292.2214