BEFORE PERFORMING ELECTRICAL WORK, READ THESE REGULATIONS
1. All wiring must comply with local and national electrical codes, and must be installed by a
licensed electrician.
2. All electrical connections must be made according to the Electrical Connection Diagram
located on the panels of the indoor and outdoor units.
3. If there is a serious safety issue with the power supply, stop work immediately. Explain your
reasoning to the client, and refuse to install the unit until the safety issue is properly resolved.
4. Power voltage should be within 90-100% of rated voltage. Insufficient power supply can
cause malfunction, electrical sock, or fire.
5. If connecting power to fixed wiring install a surge protector and main power switch with a
capacity 1.5 times the maximum unit current.
6.
If connecting power to fixed wiring, a switch or circuit breaker that disconnects all poles and
has a contact separation of at least 1/8in (3mm) must be incorporated in the fixed wiring, The
qualified technician must use an approved circuit breaker or switch.
7. Only connect the unit to an individual branch circuit outlet. Do not connect another appliance
to that outlet.
8. Make sure to properly ground the air conditioner.
9. Every wirre must be firmly connected. Loose wiring can cause the terminal to overheat,
resulting in malfunction and possible fire.
10. Do not let wires touch or rest against refrigerant tubing, the compressor, or any moving parts
within the unit.
11. If the unit has an auxiliary electric heater, it must be installed at least 40in (1 meter) away
from combustible materials.
WARNING
BEFORE PERFORMING ANY ELECTRICAL OR WIRING WORK, TURN OFF THE MAIN POWER
TO THE SYSTEM.
Indoor Unit Installation

Other manuals for MrCool Advantage Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MrCool Advantage Series and is the answer not in the manual?

MrCool Advantage Series Specifications

General IconGeneral
RefrigerantR410A
Operating Temperature Range (Cooling)5°F to 122°F
Dimensions (Indoor Unit)Varies by model
Dimensions (Outdoor Unit)Varies by model
Weight (Indoor Unit)Varies by model
Weight (Outdoor Unit)Varies by model
TypeMini-Split Air Conditioner
Cooling Capacity9, 000 - 36, 000 BTU
SEER RatingUp to 22 SEER
Power Supply208/230V, 60Hz