10
Flash power
Power supply
Guide number, 2 m, ISO 100, Reflector FILNOS 50°
F-stop, 2 m, ISO 100, Reflector FILNOS 50°
Output control range (1/8 - 1/1)
Recycling time
Flash duration, t 0.5
Halogen modeling light 100%
Halogen tube
Flash voltage stability
Connected load
Flash triggering
Radio interference suppression
Electrical safety
Dimensions
Weight
J (Ws.)
V
Ws.
sec
sec
W
E 14
KVA
mm
kg
200
220 – 240
45,5
22,1
25 – 200
0,6 – 2
1/555 – 1/1010
60
230 V / 60 W
+/– 0,5%
0,46/230 V / 2 A
Slave cell, synccable, manual,
IR, RADIO SLAVE 2
CE, According to German VDE reg.
CE, DIN IEC 491, VDE 0882
255,5 x 110 x 162
1,0
Specifications Compact Plus
Operation controls
1. Main switch ON-OFF
2. Photocell switch / IR receiver ON-OFF
3. Photocell / IR receiver
4. Manual release
5. Synchronous socket
6. Power control
7. Handle
8. Hand lever / lock
9. Cable protection
10. Tripod bushing 5/8"
11. Locking screw
12. Halogen bulb
13. Flash tube
14. Top ventilation slots
15. Bottom ventilation slots
16. Ignition bracket
17. Reflector bayonet
18. Mains connection socket
19. Name plate