Page
of
Call the AVPro Team at –North America 877-886-5112 International +1-605-274-6055
Color Cube Workflow Overview
In CalMAN, the Color Cube workflow steps you through the process of creating 3D corrective LUTs
for display calibration. There are six sections to the Color Cube workflow, outlined below.
In this guide, we discuss page 4B of the workflow; 3D Cube LUT.
a. Session Setup - Connect meter, source, and LUT devices to CalMAN.
b. Session Options – Select desired display calibration standards.
a. Gamma & ColorChecker - Measure display’s pre-calibration gamma, white balance,
and color gamut response.
b. Performance Analysis - Measure display’s pre-calibration color saturation and
luminance linearity.
c. Advanced Linearity - Pass/fail analysis of display’s key performance parameters.
a. Display Presets - Select optimal display presets for picture mode, color space, and
automatic image adjustment features.
b. Mode Settings - Select optimal display settings for color temp and gamma.
c. Dynamic Range - Adjust display’s black level and white level and test for dynamic
range compression.
d. RGB Adjust - Optimize display’s RGB white balance controls.
e. Luminance Target - Set display’s desired maximum luminance.
a. 1D Ramp LUT - Calibrate display’s gamma and grayscale tracking with a 1D ramp
LUT.
b. 3D Cube LUT - Create a 3D cube LUT to correct the display under test.
a. Gamma & ColorChecker - Validate display’s post-calibration gamma, white balance,
and gamut response.
b. Advanced Linearity - Validate display’s post-calibration color saturation and
luminance linearity.
c. Advanced 3D Luminance - Analyze display’s post-calibration luminance response for
white, color primaries, and color secondaries (WRGBCMY).
d. Eyeglass - Visually validate display performance with CalMAN Eyeglass.