MASI65-M12 User's manual
26 V 1.1
3 Installation information
3.1 Mounting
3.1.1 Screwed mounting
Modules of the MVK12 series can be attached directly to an installation panel or to a machine. Mounting
holes (A,B,C or D) are provided for this purpose.
Before attaching the module, it must be assured that the mounting surface is smooth and even to prevent
mechanical stress in the housing.
Modules are attached by three M4x12 screws.
Dimensions are the same as for passive distribution systems from Murrelektronik.
This enables an easier conversion to the AS-Interface system.
3.1.2 Screwed mounting of an 8-way module
A
B
C
D
50 mm
38 mm
73 mm
107 mm
39 mm
33 mm
Fig. 3-1 : Mounting of a MASI65-M12 8-way module