Technical Data
User manual 9000-41011-0200000_hdb_en_20 32 / 92
4.2 Mico Pro PM (power module)
4.2.1 Electrical data
4.2.1.1 Input
4.2.1.2 Control input
4.2.1.3 Output
Parameter Conditions Value
Operating voltage 12 V , 24 V
Input voltage range 9 V ... 30 V
Cut-in/cut-out frequency 0.5 Hz
Total operating current 40 A
Supply current ≥5 A
Parameter Conditions Value
CTRL input voltage Low 0 V … 1 V,
high 9 V … 30 V
CTRL control current n = Number of
Mico Pro extensions
High n x 2 mA
CTRL signal Ctrl functions 2 & 3
are available from
software version
1.06a onwards.
(XXXXXX-X.XX-
1.06a)
1 | OFF: "high" 40±3 ms
ON: "high" 20±3 ms
2 | OFF: "high" 400±30 ms
ON: "high" 200±30 ms
3 | OFF: "high" >600 ms,
ON: "high" CTRL & ON
>500 ms
CTRL switching frequency ≤10 Hz
CTRL overvoltage protection Suppressor diode 36 V
Remote switch-on (ON) Possible
ON input voltage Low 0 V … 5 V,
high 10 V … 30 V
ON control current n = Number of
Mico Pro extensions
High n x 2 mA
ON pulse length 0 V and pulse ON: high 120 ms
ON overvoltage protection Suppressor diode 36 V
Parameter Conditions Value
Parallel connection Not possible
Total operating current continuous
jumper
Plug-In link 40 A
Output current 40 A