Technical Data
User manual 9000-41011-0200000_hdb_en_20 33 / 92
4.2.1.4 Control output
4.2.2 Environmental characteristics
4.2.2.1 Climatic
4.2.2.2 Mechanical
Parameter Conditions Value
Ohmic resistance terminals "Alarm" Input voltage 0 V 100 kOhm ±1 kOhm
Ohmic resistance terminals "Alarm" Input voltage ≥9 V
Min. 1 channel in composite
off
100 kOhm ±1 kOhm
Ohmic resistance terminals "Alarm" Input voltage ≥9 V
all channel in composite off
35 Ohm ±15 Ohm
Adjustable voltage terminals
"Alarm"
≤30 V /
Current at terminal "Alarm" ≤20 mA
Parameter Conditions Value
Ohmic resistance terminals "90 %" Input voltage 0 V 100 kOhm ±1 kOhm
Ohmic resistance terminals "90 %" Input voltage ≥9 V
all channel with output cur-
rent ≤90 % trigger current
100 kOhm ±1 kOhm
Ohmic resistance terminals "90 %" Input voltage ≥9 V
min. 1 channel with output
current ≤90 % trigger cur-
rent
35 Ohm ±15 Ohm
Adjustable voltage terminals "90 %" ≤30 V /
Current at terminal "90 %" ≤20 mA
Symbol Parameter Conditions Value
Relative humidity No condensation 5 ... 85 %
Storage temperature -40 ... +80 °C
Climate class IEC/EN 60721-3-3 3K3
Ta Surrounding air temperature
range
-25 ... +55 °C
Installation height Above sea level,
without any restrictions
-500 m ... 2000 m
Installation height Above sea level,
max. 32 A total operat-
ing current
2000 m ... 4000 m
Installation height Above sea level,
max. 24 A total operat-
ing current
4000 m ... 6000 m
Parameter Conditions Value
Vibration test IEC 60068-2-6:2007 Test
Fc; EN 60068-2-6:2008
sin 5 ... 17.8 Hz: 1.6
mm;
17.8 ... 500 Hz: 2.3 g
10x f
Shock test IEC 60068-2-27:2008 Test
Ea; EN 60068-2-27:2009
1/2 sin 30 g, 11 ms
Shocks caused by rough handling (Drop test) 1 m